Placing System In Operation
After component service or replacement has been completed and all connections have been made, evacuate system thoroughly with a vacuum pump. Charge system with proper amount of refrigerant and perform leak test. See REFRIGERANT OIL & REFRIGERANT SPECIFICATIONS TABLE for system capacities. Check all fittings that have been opened. After system has been leak tested, check system performance.
NOTE:
Most compressors are pre-charged with a fixed amount of refrigerant (shipping) oil. Drain compressor oil from new compressor and add refrigerant oil to new compressor according to amount removed from old compressor. Always refer to underhood A/C Specification Label or A/C compressor label while servicing A/C system.