Function Control Motor
CAUTION:
After motor operates, remove power source as soon as possible to avoid motor damage.
Unplug function control motor connector. Apply battery voltage to motor terminal No. 5. Connect terminal No. 1 to ground. See Fig 1 . Using jumper wire, connect terminal No. 1 in turn to terminals No. 2, 3, 4, 7 and 8. If motor does not operate each time circuit is completed, replace motor.