2-Way Valve
- Remove fuel filler cap. Remove fuel tank vapor hose from 2-way valve. Connect vacuum/pressure gauge to "T" fitting and vacuum pump to hose end. See Fig 1.
- Slowly apply vacuum while observing vacuum/pressure gauge. Vacuum should stabilize momentarily between .2 and .6 in. Hg. If vacuum does not stabilize (valve opens) in specified range, replace 2-way valve and retest.