EVAP 2-Way Valve
- Remove fuel filler cap. Remove fuel tank vapor hose from EVAP 2-way valve. EVAP 2-way valve is located on fuel tank. Connect hose end to a "T" fitting connected to a vacuum/pressure gauge and vacuum pump. See Fig 1 .
- Slowly apply vacuum while observing vacuum/pressure gauge. Vacuum should stabilize (valve opens) momentarily within specified range. See EVAP 2-WAY VALVE STABILIZING PRESSURE . If vacuum stabilizes within specified range, go to next step. If vacuum stabilizes less than or more than specified range, replace EVAP 2-way valve and retest.
- Move vacuum pump and vacuum gauge from vacuum side to pressure side. See Fig 1
. Slowly pressurize vapor line while observing gauge. Pressure should momentarily stabilize (valve opens) within specified range. See EVAP 2-WAY VALVE STABILIZING PRESSURE
. If pressure stabilizes as specified, valve is okay. If pressure does not stabilize as specified, replace EVAP 2-way valve and retest.EVAP 2-WAY VALVE STABILIZING PRESSURE
Application in. Hg (kPa) Vacuum 0.2-0.6 (0.7-2.0) Pressure 0.4-1.4 (1.3-4.7)