October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Idle Speed
Ensure idle speed is set to specification. See IDLE SPEED SPECIFICATIONS . For adjustment procedures, see ADJUSTMENTS
article.
IDLE SPEED SPECIFICATIONS
| Application |
Base Idle RPM |
Curb Idle RPM |
Load Idle RPM |
| Integra |
| B18B1 & B18C1 |
430-530 |
700-800 |
700-800 |
| B18C5 |
500-600 |
800-900 |
800-900 |
| 2.3CL |
500-600 |
650-750 |
720-820 |
| 2.5TL |
500-600 |
650-750 |
720-820 |
| 3.0CL |
700-800 |
700-800 |
700-800 |
| 3.2TL |
430-530 |
590-690 |
600-700 |
| 3.5RL |
430-530 |
590-690 |
600-700 |