Security Siren Test
NOTE:
To prevent actuator damage, apply battery voltage only momentarily.
Access security siren. See COMPONENT LOCATIONS . Disconnect 3-pin connector. Remove siren. Using jumper wire, apply battery voltage to security siren connector White/Yellow wire terminal. Using another jumper wire, connect Brown wire terminal to ground. Replace siren if it fails to sound.