Check these items before using the display mode
- Turn the ignition switch ON (II), and check the recirculation door function; press the recirculation button to switch from FRESH to RECIRC. The air volume and sound should change slightly.
- Set the temperature control to the desired test temperature. When selecting the test temperatures, note these items:
2003-04 models
- 60 °F temperature setting will default to MAX COOL, VENT, and RECIRC.
- 90 °F temperature setting will default to MAX HOT, FLOOR, and FRESH.
- 61 through 89 °F settings will use the automatic climate control logic.
2005 model
- Lo temperature setting will default to MAX COOL, VENT, and RECIRC.
- Hi temperature setting will default to MAX HOT, FLOOR, and FRESH.
- 58 ° through 86 °F settings will use the automatic climate control logic.
- Turn the ignition switch OFF.