Recirculation Control Motor Replacement
- Remove the glove box (see GLOVE BOX REMOVAL/INSTALLATION
).
- Disconnect the wire harness connectors.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.