Malfunction Threshold
One of these conditions is met.
- The estimated volume of intake air is 150 l/min (158.6 US qt/min, 132.0 lmp qt/min), 190 l/min (200.8 US qt/min, 167.2 lmp qt/min) or more when the MAP value is 74 kPa (560 mmHg, 22.0 in.Hg), 34 kPa (260 mmHg, 10.2 in.Hg)*1 .
- The estimated volume of intake air is 200 l/min (211.4 US qt/min, 176.0 lmp qt/min) or more when the MAP value is 27 kPa (210 mmHg, 8.2 in.Hg), 47 kPa (360 mmHg, 14.1 in.Hg)*2 .
*1: K20A3 engine
*2: K20Z1 engine