EPS Control Unit Inputs and Outputs for Connector A (2P) (Connector Disconnected)
WARNING: This page is about a different car, the 2011 Acura TL, 2010 Acura TL, and 2009 Acura TL. However, it is still accessible from the selected car via links, so may be relevant.
CONNECTOR TERMINALS DESCRIPTION CHART
| Terminal number | Wire color | Terminal sign | Description | Signal |
|---|---|---|---|---|
| 1 | BLK | PG (Power ground) | Ground for the actuator EPS motor | Continuity to ground |
| 2 | WHT | +B (Plus battery) | Power source for the actuator EPS motor | Battery voltage at all times |