Recirculation Control Motor Replacement

WARNING: This page is about a different car, the 2006 Acura MDX, 2005 Acura MDX, 2004 Acura MDX, and 2003 Acura MDX. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove the glove box (see GLOVE BOX REMOVAL/INSTALLATION ).
  2. Disconnect the wire harness connectors.
    Fig 1: Disconnecting Wire Harness Connectors
    G03641897Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
    Fig 2: Removing Self-Tapping Screws And Recirculation Control Motor From Blower Unit
    G03641898Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.