Recirculation Control Motor Replacement
- Remove the glove box (see GLOVE BOX REMOVAL/INSTALLATION ).
- Remove the climate control unit (see CLIMATE CONTROL UNIT REMOVAL/INSTALLATION ).
- Remove the harness clip (A), the self-tapping screws and the passenger's heater duct (B).
- Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
- Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.