Switch Test/Replacement
- Remove the shift panel (see CENTER CONSOLE PANEL REMOVAL/INSTALLATION )
- Remove the seat heater switch from panel
- Check for continuity between the terminals in each switch position according to the tableNOTE:
- Make sure the correct test lead (+ or -) is placed on the terminal
- When check for continuity across the diode, use the diode setting on the digital volt/ohm meter to check the diode bias
- Be careful of the characteristic (Diode is one that conducts fully in one direction (forward) and not at all in the opposite direction (reverse))
- If the continuity is not as specified, replace the switch