Standards and Service Limits: Steering
STEERING SPECIFICATIONS
| Item | Measurement | Qualification | Standard or New | Service Limit |
|---|---|---|---|---|
| Steering wheel | Rotational play measured at outside edge | 0-10 mm (0-0.39 in) | - | |
| Initial turning load measured at outside edge with engine running | 29 N (3.0 kgf, 6.6 lbf) | - | ||
| Gearbox | Angle of rack guide screw loosened from locked position | 15±5° | ||
| Pump | Output pressure with shut-off valve closed | 9, 250-9, 750 kPa (94.32-99.42 kgf/cm2 , 1, 341.5-1, 414.1 psi) | - | |
| Power steering fluid | Capacity: use Acura power steering fluid | System capacity | 1.1 L (1.2 US qt) | - |
| Reservoir capacity | 0.36 L (0.38 US qt) | - | ||