VSA Modulator-Control Unit Connector for Inputs and Outputs (2017 2018 2019 2020)
VSA Modulator-Control Unit Inputs and Outputs for 38P Connector (female terminals)
| Terminal number | Terminal sign | Description |
|---|---|---|
| 1 | PGND | Ground for the pump motor |
| 2 | +B VSA MTR(40A) | Power source for the motor relay |
| 3 | PGND | Ground for the VSA modulator-control unit |
| 4 | FSR+B | Power source for the fail-safe relay |
| 5 | Not used | - - - |
| 6 | Not used | |
| 7 | Not used | |
| 8 | Not used | |
| 9 | FRL- | Detects left-front wheel speed sensor signal |
| 10 | Not used | - - - |
| 11 | Not used | |
| 12 | Not used | |
| 13 | FRR- | Detects right-front wheel speed sensor signal |
| 14 | BRAKE LAMP | Drives the brake light relay |
| 15 | Not used | - - - |
| 16 | Not used | |
| 17 | Not used | |
| 18 | BRAKE DIAG | Detects brake light relay |
| 19 | Not used | - - - |
| 20 | F-CAN B_L | F-CAN communication circuit |
| 21 | FRL+ | Detects left-front wheel speed sensor signal |
| 22 | RRL- | Detects left-rear wheel speed sensor signal |
| 23 | RRR+ | Detects right-rear wheel speed sensor signal |
| 24 | FRR+ | Detects right-front wheel speed sensor signal |
| 25 | Not used | - - - |
| 26 | F-CAN A_L | F-CAN communication circuit |
| 27 | Not used | - - - |
| 28 | Not used | |
| 29 | Not used | |
| 30 | Not used | |
| 31 | F-CAN B_H | F-CAN communication circuit |
| 32 | Not used | - - - |
*1: Without auto idle stop system
*2: With auto idle stop system
| Terminal number | Terminal sign | Description |
|---|---|---|
| 33 | RRL+ | Detects left-rear wheel speed sensor signal |
| 34 | Not used | - - - |
| 35 | RRR- | Detects right-rear wheel speed sensor signal |
| 36 | IG1B DR1(7. 5A) *1IG1 VSA (DC/DC) *2 | Power source for activating the system |
| 37 | Not used | - - - |
| 38 | F-CAN A_H | F-CAN communication circuit |
*1: Without auto idle stop system
*2: With auto idle stop system