EVAP Leak Check Module Pressure Sensor Inspection
NOTE: Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Test Procedure (Step 1)
- Preparation
-
- -
EVAP leak check module 8P connector: disconnected
- -
- Procedure
-
- Turn the vehicle to the ON mode.
- Confirm the HDS [Absolute Pressure of ELCM Pressure Sensor].
- Normal Conditions
-
- -
HDS [Absolute Pressure of ELCM Pressure Sensor] value is more than 852.804 mmHg.
- -
Test Procedure (Step 2)
- Preparation
-
- -
EVAP leak check module 8P connector: disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
(Disconnected) EVAP leak check module 8P connector female terminals
IG Mode
Normal Conditions
Unit output voltage inspection
ON
About 5.0 V
Results
- If it is normal, there is a problem with the EVAP leak check module.
- If it is abnormal, there is a problem with other related components.