+B_EPS Circuit Inspection
Test Procedure
- Preparation
-
- EPS control unit connector A (2P): disconnected
- Procedure
-
- Perform the inspection according to the following table.
(Disconnected) EPS control unit connector A (2P) female terminals
IG Mode
Normal Conditions
+B_EPS circuit inspection
OFF
12 V battery voltage[circuit type 1]
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.