CDS Circuit Inspection
NOTICE:
Before Disconnecting The SRS Unit Connector, Do The 12 Volt Battery Terminal Disconnection Procedure And Wait For At Least 3 Minutes.
Test Procedure
- Preparation
-
- -
SRS Unit Connector A (43P): Disconnected
- -
Body Control Module Connector B (66P): Disconnected
- -
- Procedure
-
- -
Perform The Inspection According To The Following Table.
- -
(Disconnected)SRS Unit Connector A (43P) female Terminals
(Disconnected)Body Control Module Connector B (66P) female Terminals
IG Mode
Normal Conditions
CDS Open Wire Inspection
Off
There Is Less Than 1 Ω
Refer To The Open/Shorted Wire Inspection Description
For The Method To Inspect The Shorted Circuit Below, Then Start To Inspect According To Circumstances.
CDS Shorted To Ground Inspection
Off
There Is More Than 1 MΩ
Results
- If Abnormal, There Is A Problem In The Circuit.