VTC Oil Control Solenoid Valve A Component Inspection
Test Procedure
- Preparation
-
- -
VTC oil control solenoid valve A connector (2P): disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
(Disconnected) VTC oil control solenoid valve A connector (2P) male terminals
IG Mode
Normal Conditions
Valve internal circuit inspection
OFF
About 7.14 - 7.90 Ohm (at room temperature)
Results
- If abnormal, there is a problem with VTC oil control solenoid valve A.