SO2, SO2_SG [SO2SG] Shorted Wire Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
-
- -
Secondary HO2S (Sensor 2) connector (4P) : disconnected
- -
PCM connector A (50P) : disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- -
(Disconnected) Secondary HO2S (Sensor 2) connector (4P) male terminals
IG Mode
Normal Conditions
SO2 shorted to ground inspection
OFF
There is more than 1 MOhm
SO2_SG [SO2SG] shorted to ground inspection
OFF
There is more than 1 MOhm
Results
- If abnormal, there is a problem in the circuit.