SO2, SO2_SG [SO2SG] Circuit Inspection

NOTICE: 

Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.

Test Procedure 

(Disconnected) Secondary HO2S (Sensor 2) connector (4P) male terminals

(Disconnected) PCM connector A (50P) - Refer to: PCM Connector for Inputs and Outputs (1.5L Engine) or PCM Connector for Inputs and Outputs (2.0L Engine) (2024 2025) female terminals

IG Mode

GHH653144Courtesy of HONDA, U.S.A., INC.
GHH653145Courtesy of HONDA, U.S.A., INC.

Normal Conditions

SO2 open wire inspection 

OFF

There is less than 1 Ohm 

SO2_SG [SO2SG] open wire inspection 

OFF

There is less than 1 Ohm 

Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.

SO2_SG [SO2SG] shorted to power inspection 

ON

There is less than about 5 V 

Results