IAT Sensor 2 Inspection
NOTE: Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Test Procedure
Unit output voltage inspection
- Preparation
-
- -
IAT sensor 2 connector (2P): disconnected
- -
- Procedure
-
- Jump the IAT sensor 2 connector (2P) terminals No. 1 and No. 2 with a jumper wire.
- Turn the vehicle to the ON mode.
- Confirm the HDS [IAT Sensor (2) Voltage].
(Disconnected) IAT sensor 2 connector (2P) female terminals
- Normal Conditions
-
- -
HDS [IAT Sensor (2) Voltage] value is less than 4.92 V .
- -
Results
- If it is normal, there is a problem with IAT sensor 2.
- If it is abnormal, there is a problem with other related components.