ECT Sensor 1, ECT Sensor 2 Functional Inspection
Preconditions
- Engine is cold condition (ambient temperature)
Test Procedure
- Procedure
-
- Note the ambient temperature.
- Turn the vehicle to the ON mode.
- Quickly note the HDS [ECT Sensor 1] value and the [ECT Sensor 2] value.
- Compare the HDS [ECT Sensor 1] value and the [ECT Sensor 2] value to the recorded ambient temperature individually.
- Normal Conditions
-
- -
The difference between the HDS [ECT Sensor 1] value, the [ECT Sensor 2] value, and the ambient temperature is less than 5.4 deg.F (3 deg.C ).
- -
Results
- If it is abnormal, there is a problem with the ECT sensor that differed more than 5.4 deg.F (3 deg.C) from the ambient temperature.