+B_EPS (EPS) Circuit Inspection
Test Procedure
- Preparation
-
- -
EPS control unit connector A (2P): disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
(Disconnected) EPS control unit connector A (2P) - Refer to: EPS Control Unit Connector for Inputs and Outputs (2022 2023 2024) or EPS Control Unit Connector for Inputs and Outputs (2025) female terminals
IG Mode
Normal Conditions
+B_EPS (EPS) circuit inspection
OFF
12 V battery voltage[circuit type 1]
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.