DTC Troubleshooting: U1484-68 (Radar Vision Unit) (2025): Notes
DTC U1484-68 : (Turn Signal Switch Malfunction/MICU (Body Control Module)Malfunction) (Radar Vision Unit)
How to use this service information .
NOTICE:
- Before you troubleshoot, review the How to Troubleshoot .
- Troubleshoot the following DTCs first, if stored at the same time.
-
- -
Body Electrical System [Gauge Control Module]: Go to the indicated DTC's troubleshooting .
- -
NOTE:
- If a DTC is recorded again after it is cleared with the HDS, perform a troubleshooting for the gauge control module .
- This DTC is stored when the radar vision unit receives MICU failure information from the gauge control module.