+B_SMART, SS1(+), SS2(-), GND Circuit Inspection
Test Procedure
- Preparation
-
- -
Engine start/stop switch 10P connector: disconnected
- -
Body control module connector C (66P): disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
(Disconnected) Engine start/stop switch 10P connector female terminals
(Disconnected)Body control module connector C (66P) female terminals
IG Mode
Normal Conditions
+B_SMART circuit inspection
OFF
12 V battery voltage [circuit type 1]
SS1(+) open wire inspection
OFF
There is less than 1 Ohm
SS2(-) open wire inspection
OFF
There is less than 1 Ohm
GND open wire inspection
OFF
There is less than 1 Ohm
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.