Power Distribution Module Functional Inspection
NOTE:
Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Preconditions
- External circuit is normal
Test Procedure
A/C compressor functional inspection
- Preparation
-
- Power distribution module connector A (18P): disconnected
- Power distribution module connector E (2P): disconnected
- Procedure
-
- Connect power distribution module connector A (18P) terminal No. 5 to power distribution module connector E (2P) terminal No. 1 with a jumper wire.
| (Disconnected)Power distribution module connector A (18P) female terminals | (Disconnected)Power distribution module connector E (2P) female terminals |
|
|
|
- Normal Conditions
-
- The A/C compressor clutch click.
Results
- If it is normal, there is a problem with the power distribution module.
- If it is abnormal, there is a problem with other related components.