Home >> Acura >> 2025 >> MDX Base >> Repair and Diagnosis >> Steering >> Steering Control Systems >> Body Electrical System - Troubleshooting - System Description >> Troubleshooting >> Keyless/Power Door Locks/Security System Symptom Troubleshooting - Security alarm system will not arm >> AS_SILCON_UNLOCK, GND Circuit Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

AS_SILCON_UNLOCK, GND Circuit Inspection

Test Procedure 

(Disconnected) Front passenger's door latch 10P connector female terminals

(Disconnected)Front passenger's door control unit connector C (32P) female terminals

IG Mode

GHH659445Courtesy of HONDA, U.S.A., INC.
GHH659446Courtesy of HONDA, U.S.A., INC.

Normal Conditions

AS_SILCON_UNLOCK open wire inspection 

OFF

There is less than 1 Ohm 

GND open wire inspection 

OFF

There is less than 1 Ohm 

Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.

AS_SILCON_UNLOCK shorted to ground inspection 

OFF

Not shorted 

Results