Generator Output Test
- Set ohmmeter on 100x scale. Connect ohmmeter leads between generator output terminal and all 3 stator terminals one at a time. See Fig 1
. Reverse ohmmeter leads. If ohmmeter indicates continuity in only one direction, go to next step. If ohmmeter indicates continuity in both directions, replace diode assembly.
- Connect ohmmeter leads between negative plate and all 3 stator terminals one at a time. Reverse ohmmeter leads. If ohmmeter indicates continuity in only one direction, go to next step. If ohmmeter indicates continuity in both directions, replace diode assembly.
- Connect ohmmeter leads between terminal D+ (Blue wire) terminal and all 3 stator terminals one at a time. Reverse ohmmeter leads. If ohmmeter indicates continuity in only one direction, diode assembly is okay. If ohmmeter indicates continuity in both directions, replace diode assembly.