| P0601 |
Internal Control Module Memory Check Sum Error |
|
Internal check sum, incorrect |
|
0.5 Sec |
|
| P0602 |
Control Module Programming Error |
|
Reprogramming not completed |
|
0.5 Sec |
|
| P0604 |
Internal Control Module Random Access Memory (RAM) Error |
|
Write ability check, failed |
|
0.5 Sec |
|
| P0605 |
Internal Control Module Read Only Memory (ROM) Error |
ROM area check |
Check, failed. |
|
0.5 Sec |
|
| P0606 |
ECM/PCM Processor |
|
Failed |
--- |
0.5 Sec |
|
| P0613 |
TCM Processor |
|
Check-calculation of 1st CPU failed, Single reset does not cover problem |
--- |
0.5 Sec |
|
| P0614 |
ECM/TCM Incompatible |
|
Detection of error signal |
- CAN bus, Active
- ECU communication, Active
|
250 ms |
|
| P062B |
Injector Valves Communication CPU |
|
|
Engine speed, >80 RPM |
2 Seconds |
|
| P0638 |
Throttle Actuator Control Range/Performance - Bank 1 |
|
- Time to open over reference point + 12%, > 0.14 Sec.
- Time to close below reference point, + 3%, > 0.56 Sec.
|
- Ignition, On
- Engine speed, 0 RPM
- IAT, > 5°C
- Vehicle speed, 0 MPH
|
5 Sec |
|
| P0641 |
Sensor Reference Voltage A Circuit/Open |
|
Internal Fault |
|
0.4 Seconds |
|
| P0642 |
Sensor Reference Voltage A Circuit Low |
|
Signal voltage, 4.6-5 V |
|
0.4 Seconds |
|
| P0643 |
Sensor Reference Voltage A Circuit High |
|
Signal voltage, >4.5-5.4 V |
|
0.4 Seconds |
|
| P0651 |
Sensor Reference Voltage B Circuit/Open |
|
Internal Fault |
|
0.4 Seconds |
|
| P0652 |
Sensor Reference Voltage B Circuit Low |
|
Signal voltage, 4.6-5 V |
|
0.4 Seconds |
|
| P0653 |
Sensor Reference Voltage B Circuit High |
|
Signal voltage, >4.5-5.4 V |
|
0.4 Seconds |
|
| P0657 |
Actuator Supply Voltage A Circuit/Open |
- Check Engine Component Power Supply Relay J757
|
Signal voltage, > 4.4-5.6 V |
- Relay, Commanded off
- Engine speed, > 40 RPM
|
0.5 Seconds |
|
| P0658 |
Actuator Supply Voltage A Circuit Low |
|
Signal voltage, 2.15-3.25 V |
- Relay, Commanded off
- Engine speed, 40 RPM
|
0.5 Seconds |
|
| P0659 |
Actuator Supply Voltage "A" Circuit High |
|
Signal current >1.1 A |
- Relay, Commanded on
- Engine speed, 40 RPM
|
0.5 Seconds |
|
| P0685 |
ECM/PCM Power Relay Control Circuit/Open |
|
- Control voltage, > 0.7 V
- Sense circuit voltage, 4.0 V
|
|
0.5 Seconds |
|
| P0686 |
ECM/PCM Power Relay Control Circuit Low |
|
- Control voltage, 0.51 V
- Sense circuit voltage, > 5.5 V
|
|
0.5 Seconds |
|
| P0687 |
ECM/PCM Power Relay Control Circuit High |
|
- Control voltage > 4.0 V
- Sense circuit voltage, 4.0 V
|
|
0.5 Seconds |
|
| P0688 |
ECM/PCM Power Relay Sense Circuit |
- Check voltage supply for Engine Control Module (ECM) J623 →
Voltage supply, checking .
- Check activation of Motronic Engine Control Module (ECM) Power Supply Relay J271.
|
|
|
2 Sec |
|