Reducing Agent Metering System Control Module -J880-, CHECKING
Function
The Reducing Agent Metering System Control Module -J880- controls the provides the Reducing Agent Metering System Control Module -J880- with data on current reducing agent system pressure.
Special tools and workshop equipment required
- Multimeter
- Wiring Diagram
- Scan Tool
Test Requirements
NOTE:
Reducing Agent Reservoir Sensor -G697-, Reducing Agent Temperature Sensor -G685-and Reducing Agent Tank Heater (Heating Circuit 1) -Z102- are contained within the Reducing Agent Delivery Unit Located in the right rear wheel housing under the wheel housing liner and mounts to the Active Tank. Should 1 component be faulty the whole Assembly would need to be replaced.
- Fuses OK.
- Battery voltage OK
- Switch OFF all electrical and electronic accessories.
- Vehicles with Auto. Transmission, ensure Selector Lever position is in "P".
- Vehicles with Man. Transmission, ensure Shifter Lever position is in "N" with Parking Brake applied.
- Observe all safety precautions: SAFETY PRECAUTIONS
- View clean working conditions: CLEAN WORKING CONDITIONS
Test Procedure
| Step |
Procedure |
Result / Action to Take |
| 1 |
- PERFORM: Preliminary Check to verify the customers complaint. Refer to PRELIMINARY CHECK
-- Was complaint verified? |
-- YES:
-- NO:
- Gather more Information from customer about the complaint
|
| 2 |
- DISCONNECT: Reducing Agent Metering System Control Module -J880- electrical connector T8ac
- IGNITION: ON
- CHECK: Reducing Agent Metering System Control Module -J880- harness connector terminals T8ac / 2 to T8ac / 1 and 5 for voltage.
- SPECIFIED VALUE: Battery voltage
- CHECK: Reducing Agent Metering System Control Module -J880- harness connector terminals T8ac / 7 to T8ac / 1 and 5 for voltage.
- SPECIFIED VALUE: 5 Volts
- IGNITION: OFF
-- Was value obtained? |
-- YES:
-- NO:
- CHECK: wiring for open, high resistance, short or electrical connector for damage, corrosion, loose or broken terminals
- REPAIR: faulty wiring or connector
- GO TO: Step 4
|
| 3 |
- DISCONNECT: Reducing Agent Metering System Control Module -J880- harness connector T30
- IGNITION: ON
- CHECK: Reducing Agent Metering System Control Module -J880- harness connector terminals T30 / 10 to T30 / 11, 18 and 30 for voltage.
- SPECIFIED VALUE: 5 Volts
- IGNITION: OFF
-- Was value obtained? |
-- YES:
- REPLACE: Reducing Agent Metering System Control Module -J880-. Refer to proper repair information for removal and replace procedures.
- GO TO: Step 4
-- NO:
- CHECK: wiring for open, high resistance, short or electrical connector for damage, corrosion, loose or broken terminals
- REPAIR: faulty wiring or connector
- GO TO: Step 4
|
| 4 |
- Final Procedure
- Perform a road test to verify repair.
- Do any DTC's return:
|
-- YES:
- FAULT DOES RETURN:
- Perform the diagnostic procedure for that DTC.
-- NO:
- Repair is complete, Generate readiness code. Refer to READINESS CODE
.
- Return vehicle to Customer
|