Front Corner Radar, Calibrating

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2021 Audi S8, 2021 Audi A8 e Quattro, 2021 Audi A8 Quattro, 2020 Audi S8, and 2020 Audi A8 e Quattro. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Calibration/Adjustment must be Performed if:

TIP:

Calibrating both control modules for object detection is not necessarily required. Depending on the conditions (for example, only one of the two object detection control modules was replaced, or the bumper was only painted on one side), it is sufficient to only calibrate the affected control module.

Preparing for Calibration

GWWA96-11715Courtesy of AUDI OF AMERICA, LLC
  1. Calibration Tool - Linear Laser: VAS6350/3A 
    • With "laser protective eyewear"
    • On the Calibration Tool: VAS6350A 
    • Refer to Calibration Tool - Line Laser: VAS6350/3A  Owner's Manual for handling.
  2. Calibration Tool: VAS6350A 
    • Must be parallel with the vehicle
    • Dimension -a- side sill area = dimension -a- front bumper cover area
    • Distance to the reference point on the vehicle dimension -b- = 1, 000 ± 10 mm
  3. Level
    • On the Calibration Tool: VAS6350A 
    • To check the horizontal position of the Calibration Tool: VAS6350A 
  4. Reference Point on Vehicle
    • At the start of the seam on the bumper cover
  5. Calibration Tool - Lane Change Calibration Tool: VAS6350/4 
    • If installed correctly, the vehicle electrical system voltage wire must be connected to the calibration device at the lower left.
    • Distance from the upper edge of the Calibration Tool - Lane Change Calibration Tool: VAS6350/4  to the floor: dimension -c- = 630 mm
  6. Scale
    • Adjust the distance of the mount for the Calibration Tool - Lane Change Calibration Tool: VAS6350/4 
    • Dimension -d- = 540 mm on the scale
  7. Calibration Tool - Spacing Laser: VAS6350/2A 
    • For distance measurement
    • Refer to the Calibration Tool - Spacing Laser: VAS6350/2A  Operating Instructions for handling.

Preliminary Work

Procedure 

GWWA96-11801Courtesy of AUDI OF AMERICA, LLC

-- Position the Calibration Tool: VAS6350A  parallel to the vehicle.

-- Move the level -arrow- on the Calibration Tool: VAS6350A  so that it balances horizontally by turning the plastic feet.

GWWN91-12608Courtesy of AUDI OF AMERICA, LLC

-- Wear "laser protective eyewear".

GWWA96-11801Courtesy of AUDI OF AMERICA, LLC

-- Install the Calibration Tool - Linear Laser: VAS6350/3A  to the Calibration Tool: VAS6350A  and turn on.

-- Align the Calibration Tool: VAS6350A  .

-- Attach the Calibration Unit for Lane Change Assist: VAS6350/4  to the Calibration Tool: VAS6350A  and align.

GWWA96-11802Courtesy of AUDI OF AMERICA, LLC

-- Connect the Calibration Tool - Lane Change Calibration Tool: VAS6350/4  -1- to the vehicle electrical system voltage and switch it on at the voltage switch -2-.

GWWN94-13757Courtesy of AUDI OF AMERICA, LLC

-- If the red LED -3- turns on, then check the Calibration Unit for Lane Change Assist: VAS6350/4  -1-.

-- Using the Calibration Tool - Spacing Laser: VAS6350/2A  , measure the distance from the Calibration Tool - Lane Change Calibration Tool: VAS6350/4  -3- to the reference point on the vehicle and adjust to dimension -b-. Refer to the Calibration Tool - Spacing Laser VAS6350/2A Operating Instructions.

GWWA96-11723Courtesy of AUDI OF AMERICA, LLC

-- To adjust the dimension -b-, move the Calibration Tool: VAS6350A  sideways.

Calibration Procedure

The following should not occur during the calibration procedure:

-- Connect the Vehicle Diagnostic Tester.

-- Switch the ignition on.

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

Procedure for Control Module for Right Front Object Detection Radar Sensor

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

Procedure for Control Module for Left Front Object Detection Radar Sensor

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

-- Switch off the ignition after successful calibration.

-- Disconnect the Vehicle Diagnostic Tester from the diagnostic connection.

-- Disconnect the battery charger. Refer to BATTERY, CHARGING .