64 99... Reading out flashcode
Test Precondition:
Check function of independent park heater, refer to 64 12 005 CHECKING FUNCTION OF INDEPENDENT HEATING (THERMO TOP S) .
Instruction:
Connect inspection lamp to glow plug above peripherals box. Switch on independent heating via MID or on-board monitor, switch off after 3 minutes running time and, once after-running time has elapsed, count the number of flash pulses.
NOTE:
If there is a fault, park heating switches to fault overrun automatically after 2 minutes.
Flashcode Evaluation:
FLASHCODE EVALUATION
| Flash pulses | Fault cause and corrective measures |
|---|---|
| 1. | Flame detector has short or break, refer to FAULT 02 FLAME DETECTOR . |
| 2. | Overvoltage or undervoltage at heater, charge battery. |
| 3. | Temperature sensor has short-circuit, refer to FAULT 05 TEMPERATURE SENSOR . |
| 4. | Flame detector defective (does not detect flame), refer to FAULT 02 FLAME DETECTOR . |
| 5. | Flame detector defective (always detects flame), refer to FAULT 02 FLAME DETECTOR . |
| None. | Combustion air blower or, refer to FAULT 01 COMBUSTION AIR BLOWER , glow plug or, refer to FAULT 03 GLOW PLUG , metering pump defective, refer to FAULT 06 PARK HEATING METERING PUMP . |