S85 - DME O2 Sensor Faults 2742/2743 (12 21 08)
Publication date: 2009-04-10Reference number: 12 21 08
S85 - DME O2 SENSOR FAULTS 2742/2743
TECHNICAL SERVICE BULLETIN
| BMW: | M5, M6 with the S85 engine produced up to 3/08 |
| GROUP: | Engine Electrical Systems |
SUBJECT
S85 - DME O2 Sensor Faults 2742/2743
SITUATION
The customer complains that the "Service Engine Soon" (MIL) lamp is illuminated.
The DME fault codes "2742-Oxygen sensor diagnostic heater resistance VKAT bank 1" and/or "2743-Oxygen sensor diagnostic heater resistance VKAT bank 2" are stored in the DME.
The environmental conditions show a heater resistance between 12.5 Ohm and 13 Ohm, and there are no other O2 sensor faults stored in the DME.
There is no driveability complaint associated with this issue.
CAUSE
DME calibration
PROCEDURE
Only if the current vehicle integration level is E060-07-09-530 or lower, program the vehicle using the latest ISTA/P version.
Once the programming and coding session is completed, perform a test drive until the engine is at full operating temperature, followed by an extended idle of 10 minutes. Read the fault memory again and if the faults do not recur, release the vehicle to the customer.
If these oxygen sensor faults recur, or if the current integration level is higher than E060-07-09-530, continue troubleshooting by following the corresponding diagnostic test plans.
WARRANTY
Parts and labor will be reimbursable under the terms of the applicable BMW New Limited Warranty or BMW Emissions Warranty.
| Defect Code: | 11 78 02 14 00 - (1) Main work | |||
|---|---|---|---|---|
| Labor Operation: | Labor Allowance: | Description: | ||
| 61 00 801(1) | 7 FRU | Reprogram and recode control units (without CAS) | ||
| or | ||||
| 61 00 811(1) | 8 FRU | Reprogram and recode control units (including CAS) | ||
|
||||