Refrigerant Recovery
CAUTION:
If variation is noted in service procedures, follow the manufacturer's instructions on refrigerant recovery/recycle system.
- Close both valves on manifold gauge set. Connect manifold gauge set to high and low side service valves. See SERVICE VALVE LOCATIONS in this article.
- Connect center hose on manifold gauge set to inlet port on Refrigerant Recovery/Recycle System (J-38100-B). Start engine. Turn A/C on for approximately 2 minutes.NOTE: Operating A/C for 2 minutes will warm the refrigerant so refrigerant recovery/recycle system can recover more refrigerant from the system.
- Shut engine off. Open BOTH valves on manifold gauge set. Open BOTH valves on refrigerant recovery/recycle system storage tank at the same time.
- Plug refrigerant recovery/recycle system in and turn power switch on. Depress compressor START switch and note that the compressor ON light is activated.
- The refrigerant recovery/recycle system will shut off when a vacuum reading of 17 in. Hg is obtained on manifold gauge set. Manifold gauge vacuum reading should remain at 17 in. Hg for at least 2 minutes.
- If reading increases to above zero, refrigerant still remains in the vehicle A/C system. Depress compressor START switch and operate refrigerant recovery/recycle system through another cycle.
- Once refrigerant is recovered, open accumulator pressure valve on the refrigerant recovery/recycle system for 15 seconds. This will pressurize the oil separator so refrigerant oil can be drained.
- Open OIL DRAIN valve on the refrigerant recovery/recycle system and drain refrigerant oil into a container. Measure exact amount of oil to be added when system is put back in service.