Circuit Description
The heated oxygen sensor (HO2S) heater reduces the time required for the oxygen sensor (O2S) to reach operating temperature and maintains the operating temperature during extended idle periods. When the ignition is turned to the ON position, ignition voltage is supplied directly to the sensor heater. The engine control module (ECM) controls the heater operation by first modulating the control circuit to ground when the sensors are cold. This prevents the possibility of thermal shock to the sensor, from condensation build-up on the sensor, by controlling the sensors rate of heating. After a predetermined amount of time, the ECM commands the heaters ON continuously. Once the sensor reaches operating temperature, the ECM may modulate the heater control circuit to ground, to maintain a desired temperature.
The ECM controls the heater by grounding the control circuit with a solid state device called a driver. The driver is equipped with a feedback circuit that is pulled-up to voltage. The ECM can determine if the control circuit is open, shorted to ground, or shorted to a voltage by monitoring the feedback voltage.
The ECM calculates the HO2S heater element resistance based on the internal HO2S sensing element. If the ECM detects that the HO2S heater element resistance is too high, this DTC sets.