Front Door Window Regulator And Motor: Notes
CAUTION:
To prevent personal injury after removing regulator and motor assembly, lock sector gear to back plate before removing motor. Drill a 1/8" hole through sector gear and back plate, no closer than 1/2" from edge of sector gear. Install a metal screw (3/4" long) to lock gear, then remove motor.