LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 1987 >> Cimarron V6-173 2.8L >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Function Selector Positions >> Crossover Count
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Crossover Count



The Oxygen (O2) sensor voltage fluctuates around a threshold voltage: the value of which is stored in the PROM. A counter within the Electronic Control Module (ECM) `counts' the number of times that actual oxygen sensor voltage crosses this threshold to indicate how fast the sensor is oscillating. The crossover count is the a value representing the number of times that the sensor value crosses this threshold in 1.25 seconds. A higher crossover count number indicates a more closely air/fuel mixture ratio.