Non-controller Equipped
- With engine at normal operating temperature, increase engine speed to about 1500 RPM. Tap on engine lift hook bracket while observing engine timing. If timing retards system is operating properly.
- If timing did not retard in step 1), disconnect knock sensor. Connect voltmeter positive lead to knock sensor and negative lead to ground. Set voltmeter on 2-volt AC scale.
- Tap on engine block near knock sensor. Voltage should be indicated while tapping on block. If voltage is indicated, check for improper installation of MEM-CAL. If installed properly, replace faulty MEM-CAL or ECM. If voltage is not indicated, replace knock sensor.