Output Displays
Output displays are operated as defined under SELECTING TEST . When trouble shooting a malfunction, ECM and BCM output cycling can be used to determine if output tests can be actuated regardless of inputs and normal program instructions. Once a test in outputs has been selected, test will display HI and LO for three seconds in each state to indicate the command. The following are a summary of each parameter for BCM:
- BO00 - NO OUTPUTS
The display will not display "HI" or "LO" as this is a resting spot where no outputs will be cycled. - BO03 - RETAINED ACCESSORY POWER (RAP)
The relays display is "LO" when the relays are on (energized) . - BO07 - PARK CONTROL
Will cycle the Park output to the memory seat. Reads "LO" in Park and "HI" in all other gears. - BO09 - REDUNDANT RELAYS
Will cycle the Redundant Relays with the headlamp switch on, which will light the left low beam headlamp and left rear tail lamp. The relays are activated with the "HI" reading. - BO10 - CHIME
Cycles chime output to chime module. Chimes will not be activated with key on. - BO11 - CENTRAL DOOR UNLOCK
Will cycle the unlock coil of the door lock relay. - BO12 - THEFT DETERRENT DISABLE
Cycles the disarm output to the theft module. The display is "LO" when disarm is commanded.