LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 1989 >> Eldorado >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> DFI ECM Tests W/Codes >> Diagnostic Charts >> ECM Code EO31 - Shorted Map Sensor Circuit >> Notes On Intermittents
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Notes On Intermittents

Manipulate affected wiring and connectors while observing ECM parameter ED02. Apply and release vacuum to MAP sensor vacuum port using a vacuum source. If ECM parameter ED02 displays greater than 105 kPa, condition has been induced and cause of intermittent should be repaired. If wiring and connectors are okay, substitute a known good sensor and re-test.

Review snapshot data parameters stored with this code to verify failure. If failure is verified, check and repair intermittent wiring connection or sensor.

Fig 1: ECM Code E031, Shorted Map Sensor Circuit Schematic
G57333
Fig 2: Flow Chart, Code E031, Shorted Map Sensor Circuit