Conditions For Setting Code
B119 will set if the ignition is on and the signal voltage indicates more than 98% (open circuit) or less than 3 % (short circuit). During the time the failure is present, a substitute light reading (indicating darkness) will be implemented to allow continued operation of the headlamps The measure of light reading BD44 will however, display the actual sensor reading.