Circuit Description
This test is used in conjunction with the pre-converter oxygen sensor slow response diagnostic test (DTC P0139). The ratio of the response times that was calculated are compared to calibrated limits. If the number of both lean-to-rich transitions (switches) and rich-to-lean transitions were both zero, then the ratio will be set to zero. Other wise, the ratio is calculated based on which average response time was greater.