DTC PZ2016, Loss Of Serial Communications - Pcm: Notes
Every 5 seconds while ignition switch is in RUN position, control modules that communicate on class 2 data bus transmit a performance condition signal to Powertrain Control Module (PCM), indicating system is operating properly. Signal is then transmitted to PZM. DTC PZ2016 will set when PZM does not receive signal from PCM after 3 consecutive monitoring cycles. DTC PZ2016 will clear when PCM transmits signal to PZM.
If multiple class 2 codes are set as current (i.e., PZ2016, PZ2096, PZ2128, PZ2152, PZ2153), check for short to ground or battery in circuit between PCM and individual control modules.