Power Doors Diagnostic System Check
- Turn ignition off. Connect scan tool to Data link Connector (DLC). Turn ignition on. Attempt to establish communication with Memory Mirror Module (MMM). If scan tool communicates with MMM, go to next step. If scan tool does not communicate with MMM, go to SCAN TOOL DOES NOT COMMUNICATE WITH CLASS 2 DEVICE
under SELF-DIAGNOSTIC SYSTEM in BODY CONTROL MODULES - ELDORADO article.
- Display DTCs for MMM using scan tool. If any MMM DTCs are set, go to MEMORY MIRROR MODULE DIAGNOSTIC TROUBLE CODES
table. If no MMM DTCs are set, go to next step.
- If customer complaint is with power mirrors, go to OUTSIDE MIRROR SYSTEM CHECK
under TROUBLE SHOOTING. If customer complaint is not with power mirrors, go to next step.
- If customer complaint is with power door locks, go to POWER DOOR LOCKS - ELDORADO
article. If customer complaint is with power windows, go to POWER WINDOWS - ELDORADO
article.
MEMORY MIRROR MODULE DIAGNOSTIC TROUBLE CODES
| DTC |
Description |
| B1656 |
EEPROM Write Error |
| B1658 |
EEPROM Checksum Error |
| B1982 |
Source/Battery Voltage High |
| B1983 |
Source/Battery Voltage Low |
| B2130 |
Memory 1 Key Malfunction |
| B2131 |
Memory 2 Key Malfunction |
| B2132 |
Memory Exit Key Malfunction |
| B2133 |
Memory Set Key Malfunction |
| B2140 |
Mirror Up Switch Malfunction |
| B2141 |
Mirror Down Switch Malfunction |
| B2142 |
Mirror Left Switch Malfunction |
| B2143 |
Mirror Right Switch Malfunction |
| B2144 |
Driver Mirror Vertical Sensor Short To Ground |
| B2145 |
Driver Mirror Vertical Sensor Short To Battery |
| B2146 |
Driver Mirror Horizontal Sensor Short To Ground |
| B2147 |
Driver Mirror Horizontal Sensor Short To Battery |
| B2148 |
Passenger Mirror Vertical Sensor Short To Ground |
| B2149 |
Passenger Mirror Vertical Sensor Short To Battery |
| B2150 |
Passenger Mirror Horizontal Sensor Short To Ground |
| B2151 |
Passenger Mirror Horizontal Sensor Short To Battery |
| U1016 |
Loss Of Communication With PCM |
| U1064 |
Loss Of Communication With PZM |
| U1255 |
Class 2 Initialization Error |
| U1300 |
Class 2 Serial Data Line Short To Ground |
| U1301 |
Class 2 Serial Data Line Short To Voltage |