LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Cadillac >> 2002 >> Escalade EXT >> Repair and Diagnosis >> Restraints >> Restraints Control Systems >> Supplemental Inflatable Restraint System Deactivation Procedures >> Ford Motor Co. >> Disabling & Activating Air Bag System >> Activating System (Villager)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Activating System (Villager)

Disconnect negative battery cable. Wait at least 3 minutes to deplete charge in backup power supply. Disconnect and remove air bag simulators from vehicle. Reconnect driver's side and passenger's side air bag module connectors. Reconnect negative battery cable. Recheck system operation. Perform SYSTEM OPERATION CHECK . Reprogram radio preset frequencies and set clock.