Fastener Tightening Specifications
Fastener Tightening Specifications
| Description of Usage |
Ref No. |
Qty |
Size |
Specification |
| Metric |
English |
| Accumulator Housing to Valve Body |
318 |
12 |
M6x1.0x30.0 mm |
11 N.m |
8 lb ft |
| Channel Plate to Valve Body |
300 |
7 |
M6x1.0x38.0 mm |
11 N.m |
8 lb ft |
| Converter Housing to Case |
2 |
7 |
M8x1.25x35.0 mm |
22 N.m |
16 lb ft |
| Drain Plug to Fluid Pan |
63 |
1 |
M14x1.5x10.0 mm |
20 N.m |
15 lb ft |
| Extension Housing to Case |
35 |
7 |
M8x1.25x35.0 mm |
22 N.m |
16 lb ft |
| Fluid Pan to Case |
65 |
20 |
M6x1.0x16.0 mm |
11 N.m |
8 lb ft |
| Front Control Valve Body to Top Channel Plate |
50 |
2 |
M6x1.0x38.0 mm |
11 N.m |
8 lb ft |
| Input Speed Sensor to Case |
45 |
1 |
M6x1.0x20.0 mm |
11 N.m |
8 lb ft |
| Output Speed Sensor to Case |
43 |
1 |
M6x1.0x30.0 mm |
11 N.m |
8 lb ft |
| Parking Pawl Actuator Bracket to Case |
609 |
2 |
M8x1.25x25.0 mm |
22 N.m |
16 lb ft |
| Prop Shaft Flange to Output Shaft |
34 |
1 |
M22x1.5x10.0 mm |
57 N.m |
42 lb ft |
| Torque Converter Housing Seal Bolt |
228 |
2 |
M4x0.7x10.0 mm |
3.6 N.m |
31.86 lb in |
| Transmission Fluid Pump Cover to Torque Converter Housing |
240 |
6 |
M6x1.0x40.0 mm |
11 N.m |
8 lb ft |
| Transmission Fluid Pump Cover to Torque Converter Housing |
241 |
5 |
M8x1.25x40.0 mm |
22 N.m |
16 lb ft |
| Transmission Level Hole Plug to Case |
36 |
1 |
M18x1.5x12.0 mm |
20 N.m |
15 lb ft |
| Transmission Pressure Test Plug to Case |
40 |
1 |
M10x1.0x8.0 mm |
11 N.m |
8 lb ft |
| Valve Body to Case |
49 |
2 |
M6x1.0x50.0 mm |
11 N.m |
8 lb ft |
| Valve Body to Case |
51 |
6 |
M6x1.0x50.0 mm |
11 N.m |
8 lb ft |
| Valve Body to Case |
53 |
1 |
M6x1.0x68.0 mm |
11 N.m |
8 lb ft |
| Valve Body to Channel Plate |
53 |
1 |
M6x1.0x68.0 mm |
11 N.m |
8 lb ft |