Removal Procedure
IMPORTANT:
Use care when handling the mass air flow/intake air temperature (MAF/IAT) sensor. Do not dent, puncture, or otherwise damage the honeycell located at the air inlet end of the MAF/IAT. Do not touch the sensing elements or allow anything including cleaning solvents and lubricants to come in contact with them. Use a small amount of a non-silicone based lubricant, on the air duct only, to aid in installation.
- Remove the air cleaner outlet duct. Refer to Air Cleaner Resonator Outlet Duct Replacement .
- Pull out the gray connector position assurance (CPA) retainer.
- Push down on the black clip in order to disconnect the MAF/IAT sensor electrical connector (4).
- Loosen the MAF/IAT clamp.
- Remove the MAF/IAT sensor from the air cleaner assembly.