Scan Tool Output Controls
Scan Tool Output Controls
| Scan Tool Output Control | Additional Menu Selection(s) | Description |
|---|---|---|
| Engine Output Controls | GEN L-Terminal | The engine control module (ECM) commands the generator OFF by removing the 5 V reference signal from the L terminal of the voltage regulator when you select Off. The generator will then stop generating an output voltage. |
| Engine Output Controls | Starter Relay Control | The engine control module (ECM) grounds the starter relay control circuit when ON is selected. When Off is selected, ground is removed from the circuit |