Scan Tool Output Controls

WARNING: This page is about a different car, the 2007 GMC Sierra and 2007 Chevrolet Silverado. However, it is still accessible from the selected car via links, so may be relevant.
HVAC Control Module Scan Tool Output Controls

Scan Tool Output Control Additional Menu Selection(s) Description
A/C Permission Miscellaneous Tests When you select ON, the HVAC control module changes the state of the A/C Permission parameter to Granted and transmits a clutch enable message to the PCM over the class 2 serial data circuit. The A/C compressor clutch engages and remains engaged until you select OFF. When you select OFF, the HVAC control module changes the state of the A/C Permission parameter to Withheld and transmits a clutch disable message to the PCM over the class 2 serial data circuit.
Left Mix Motor Motor/Actuator Tests When you select ON, the HVAC control module commands the left air temperature actuator toward the maximum door position. The actuator moves the door to the full hot position. When you select OFF, the HVAC control module commands the left air temperature actuator toward the minimum door position. The actuator moves the door to the full cold position.
Mode 1 Door Position Motor/Actuator Tests When you select ON, the HVAC control module commands the mode actuator toward the maximum door position. The actuator moves the door to the panel position. When you select OFF, the HVAC control module commands the mode actuator toward the minimum door position. The actuator moves the door to the floor position.
Right Mix Motor Motor/Actuator Tests When you select ON, the HVAC control module commands the right air temperature actuator toward the maximum door position. The actuator moves the door to the full cold position. When you select OFF, the HVAC control module commands the right air temperature actuator toward the minimum door position. The actuator moves the door to the full hot position.
PCM Scan Tool Output Controls

Scan Tool Output Control Additional Menu Selection(s) Description
A/C Relay Engine Output Controls The engine must be running and the PCM must receive an A/C request from the HVAC control module in order to enable the output control. The PCM de-energizes the A/C compressor clutch relay when you select OFF. The relay remains de-energized until you select ON.